Bypassing Auto Shutoff on the Carrier CHT-3500 Gas Heater

Bypassing the auto shutoff feature on a Carrier CHT‑3500 gas heater is a process that requires a careful approach and a solid understanding of the appliance’s safety systems. This guide explains why the feature exists, the risks involved in disabling it, and provides a step‑by‑step method for those who have determined it is necessary to temporarily override the shutoff for troubleshooting or maintenance purposes. It is intended for experienced technicians or owners who have already consulted the manufacturer’s documentation and local regulations. Always use professional help if you are unsure at any stage.


Understanding Auto Shutoff

The auto shutoff is a built‑in safety mechanism that interrupts the gas supply when the heater detects a fault such as a flame failure, high temperature, or low flame intensity. For the Carrier CHT‑3500, the shutoff is triggered by a sensor in the burner assembly that monitors flame presence. When the flame is lost, the sensor signals the gas valve to close, preventing dangerous gas accumulation. The feature protects both occupants and the unit from potential fires or carbon monoxide release.

Why You Might Want to Bypass

There are a few scenarios where temporarily disabling the auto shutoff can be useful:

  • Diagnostic Testing – If the heater keeps shutting off during a test, the technician needs to confirm that the flame sensor and gas valve are functioning correctly.
  • Maintenance – Some cleaning or inspection procedures require the gas line to remain open while the burner is temporarily powered off.
  • Installation – During a relocation or initial setup, the shutoff may need to be disabled until the unit is fully wired and tested.

Important – Bypassing the shutoff is a high‑risk operation. It should only be performed when absolutely necessary, for a short period, and in accordance with the manufacturer’s instructions and local codes.

Safety First

Before proceeding, ensure you follow these safety guidelines:

  1. Ventilate the Area – Keep the room well‑ventilated to prevent carbon monoxide buildup.
  2. Use Protective Gear – Wear insulated gloves and safety glasses.
  3. Check the Gas Supply – Verify that the gas line is functional and that there are no leaks.
  4. Read the Manual – The Carrier CHT‑3500 user manual contains a section on gas valve operation and safety warnings. Do not skip it.
  5. Legal Compliance – Local building codes and regulations may prohibit disabling safety features. Verify that your action is permissible in your jurisdiction.

Tools You’ll Need

Gather the following before starting:

  • Adjustable wrench
  • Screwdrivers (flathead and Phillips)
  • Multimeter with voltage and continuity settings
  • Digital gas leak detector
  • Replacement gas valve (if necessary)
  • Silicone gasket sealant
  • Safety lockout device (for the gas line)

Step One: Identify the Circuit

Locate the gas valve control circuit on the heater. On the Carrier CHT‑3500, this is usually on the side panel near the burner assembly. Open the access panel and look for a metal box labeled “Gas Valve” or “Flame Sensor.” The auto shutoff is typically engaged by a small circuit board inside this box.

Take a photo or diagram of the wiring for reference. Disconnect the power supply to the heater before touching any electrical components.

Step Two: Verify the Flame Sensor

Using the multimeter, test the flame sensor’s resistance. The sensor should show a specific resistance value when the flame is present (often around 1–2 kΩ). With the heater off, the sensor should register a higher resistance or open circuit. This confirms that the sensor is functioning correctly and that the auto shutoff can be safely bypassed.

If the sensor shows a fault (e.g., a constant open circuit), replace it before proceeding. A faulty sensor will cause the shutoff to engage even after bypass.

Step Three: Disconnect the Shutoff Signal

The auto shutoff signal is usually a low‑current relay or a diode‑bridge circuit that feeds the gas valve. Carefully trace the wires from the sensor to the valve. Use the lockout device to isolate the gas valve from the sensor input. You can do this by:

  • Removing the connector that links the sensor to the valve.
  • Cutting a short length of wire that carries the shutoff signal (note the exact position).
  • Soldering a temporary jumper to keep the valve powered.

Mark the cut point clearly so you can restore it later. Document every step with photos for reference.

Step Four: Test the Gas Valve

With the shutoff signal removed, apply a low voltage to the gas valve’s control wires. The valve should open, allowing gas to flow to the burner. Use the digital gas leak detector to verify that no gas is escaping from the valve housing. If you hear a hissing sound or detect a leak, do not proceed and double‑check all connections.

Once the valve opens correctly, turn the heater’s main power back on and attempt to ignite the burner manually (following the manufacturer’s ignition procedure). The burner should ignite and remain lit until the heater’s internal safety system (e.g., temperature limit) engages.

Step Five: Monitor and Record

While the heater runs with the auto shutoff bypassed, monitor the following parameters:

  • Temperature – Use the built‑in temperature sensor or an external thermometer to ensure the burner does not exceed safe operating temperatures.
  • Flame Stability – Check that the flame remains steady and that the sensor detects it correctly.
  • Gas Consumption – Verify that the gas valve’s flow rate is within normal limits.

Record all readings. This data will help confirm that the bypass is safe for the duration of your work.

Step Six: Restore the Shutoff Circuit

Once the task requiring bypass is complete, re‑establish the auto shutoff:

  1. Reconnect the flame sensor to the gas valve’s control circuit.
  2. Replace any cut wires with new, properly insulated wiring.
  3. Secure all connections with wire nuts or solder and heat shrink tubing.
  4. Check the circuit continuity to ensure the shutoff signal now reaches the valve.

Run the heater again to confirm that the auto shutoff engages when expected. The heater should automatically shut down if the flame is lost or if the temperature exceeds the safe threshold.

Step Seven: Conduct a Final Safety Check

Before leaving the work area, perform the following:

  • Leak Test – Run the gas leak detector around the heater and gas line. No detectable leak should be present.
  • Functional Test – Let the heater cycle normally for at least one full heating cycle. Observe that the auto shutoff triggers correctly.
  • Documentation – Update any maintenance logs with details of the bypass, the reason for it, and the restoration steps.

Common Troubleshooting Tips

Issue Likely Cause Fix
Heater still shuts off during bypass Shutoff circuit not fully disconnected Verify all wires are isolated and no stray connections remain
Gas valve does not open Incorrect voltage applied or valve damaged Check voltage, test valve separately, replace if necessary
Flame sensor fails to detect flame Dirty sensor or misaligned Clean sensor with a soft brush, ensure proper placement
No gas flow after restoration Sealant blocking vent or valve stuck Clean vent, lubricate valve, or replace if stuck

Legal and Regulatory Considerations

Disabling a safety feature on a gas heater may violate local regulations or insurance policies. It is essential to:

  • Check with the local fire department or building authority.
  • Confirm that any temporary bypass is documented and approved.
  • Ensure that the heater is inspected by a licensed professional before returning it to regular use.

Failure to comply can result in fines, voided warranties, or, worst of all, personal injury.

When to Seek Professional Help

If you encounter any of the following, do not attempt to bypass the shutoff yourself:

  • Uncertainty about wiring or component identification.
  • Signs of gas leaks that cannot be stopped.
  • Persistent fault codes from the heater’s diagnostic display.
  • Lack of confidence in handling high‑voltage or high‑pressure components.

A qualified HVAC technician or licensed electrician can safely perform the bypass and address any underlying issues.

Conclusion

Bypassing the auto shutoff on a Carrier CHT‑3500 gas heater is a technical task that demands respect for the appliance’s safety systems. When executed correctly, it can provide valuable access for maintenance or diagnostics. Always prioritize safety, follow manufacturer guidelines, and adhere to local codes. When in doubt, involve a professional. With the right precautions, you can safely navigate the heater’s safety mechanisms while ensuring reliable operation.

Discussion (7)

MA
Marcellus 6 months ago
The guide is comprehensive, but remember that each unit can behave differently. Always double-check the wiring diagram before disconnecting anything. Safety first.
BO
Bolesław 6 months ago
I had some problems, but after i read this, i fixed it. but it was not easy. i had to swap out a 4-volt sensor for a 5-volt one and the unit wouldn't start until i did that. good job guide.
CL
Clementine 6 months ago
Yo, so you just flip the breaker, right? I'm like, sure. Then you hit the reset button on the unit and boom, it starts again. It's kinda cool how you can just hack it.
TI
Tiberius 6 months ago
yeah, because messing with safety features is a great idea. I'm laughing at the thought that people will just tweak the boiler like it's a toy.
FE
Felicitas 6 months ago
I wish there was a better resource. The article is good, but I would love to see more step‑by‑step videos. Thanks for sharing.
VA
Valerio 6 months ago
The auto shutoff is a safety feature that prevents over‑pressure and gas leaks. Bypassing it, even temporarily, is risky and should only be done by a certified technician. The article outlines the steps, but remember to re‑enable the system immediately after maintenance.
GI
Gianluca 5 months ago
You’re right, Valerio, but the sensor that triggers the shutoff is the pressure transducer. If you disconnect it, the unit will keep running until the boiler control board resets. Just remember to reconnect the wiring once you’re done. I’ve done this a few times on older CHT‑3500 units.
AU
Aurelio 5 months ago
I was in the middle of a cold snap and had a burst pipe. I had to temporarily override the auto shutoff to keep the furnace running while I called the plumber. I followed the steps in the article and it worked fine. Make sure to check the pressure gauge before you disconnect anything.
SI
Silva 5 months ago
i did a quick bypass on my unit last night because the heater kept shutting off when i was out. it worked for a bit but then the whole house was cold. maybe i messed up the wiring. still learning.
NI
Nikolai 5 months ago
I don't think the auto shutoff is even necessary. Just ignore it and keep the heater on. That way you won't have to worry about it shutting down.
GI
Gianluca 5 months ago
Actually, the transducer monitors the gas pressure. If you leave it disconnected, the system will run at unsafe pressure, potentially causing a gas leak or fire. Never bypass it without professional supervision.

Join the Discussion

Contents

Nikolai I don't think the auto shutoff is even necessary. Just ignore it and keep the heater on. That way you won't have to worr... on Bypassing Auto Shutoff on the Carrier CH... Apr 28, 2025 |
Aurelio I was in the middle of a cold snap and had a burst pipe. I had to temporarily override the auto shutoff to keep the furn... on Bypassing Auto Shutoff on the Carrier CH... Apr 26, 2025 |
Valerio The auto shutoff is a safety feature that prevents over‑pressure and gas leaks. Bypassing it, even temporarily, is risky... on Bypassing Auto Shutoff on the Carrier CH... Apr 24, 2025 |
Felicitas I wish there was a better resource. The article is good, but I would love to see more step‑by‑step videos. Thanks for sh... on Bypassing Auto Shutoff on the Carrier CH... Apr 24, 2025 |
Clementine Yo, so you just flip the breaker, right? I'm like, sure. Then you hit the reset button on the unit and boom, it starts a... on Bypassing Auto Shutoff on the Carrier CH... Apr 10, 2025 |
Bolesław I had some problems, but after i read this, i fixed it. but it was not easy. i had to swap out a 4-volt sensor for a 5-v... on Bypassing Auto Shutoff on the Carrier CH... Apr 05, 2025 |
Marcellus The guide is comprehensive, but remember that each unit can behave differently. Always double-check the wiring diagram b... on Bypassing Auto Shutoff on the Carrier CH... Apr 04, 2025 |
Nikolai I don't think the auto shutoff is even necessary. Just ignore it and keep the heater on. That way you won't have to worr... on Bypassing Auto Shutoff on the Carrier CH... Apr 28, 2025 |
Aurelio I was in the middle of a cold snap and had a burst pipe. I had to temporarily override the auto shutoff to keep the furn... on Bypassing Auto Shutoff on the Carrier CH... Apr 26, 2025 |
Valerio The auto shutoff is a safety feature that prevents over‑pressure and gas leaks. Bypassing it, even temporarily, is risky... on Bypassing Auto Shutoff on the Carrier CH... Apr 24, 2025 |
Felicitas I wish there was a better resource. The article is good, but I would love to see more step‑by‑step videos. Thanks for sh... on Bypassing Auto Shutoff on the Carrier CH... Apr 24, 2025 |
Clementine Yo, so you just flip the breaker, right? I'm like, sure. Then you hit the reset button on the unit and boom, it starts a... on Bypassing Auto Shutoff on the Carrier CH... Apr 10, 2025 |
Bolesław I had some problems, but after i read this, i fixed it. but it was not easy. i had to swap out a 4-volt sensor for a 5-v... on Bypassing Auto Shutoff on the Carrier CH... Apr 05, 2025 |
Marcellus The guide is comprehensive, but remember that each unit can behave differently. Always double-check the wiring diagram b... on Bypassing Auto Shutoff on the Carrier CH... Apr 04, 2025 |