HOME APPLIANCES

Resolving a Flame Delay on the Daikin 500 Gas Heater

8 min read
#heater troubleshooting #home heating #Flame Delay #Daikin heater #Gas heating
Resolving a Flame Delay on the Daikin 500 Gas Heater

Understanding Flame Delay on the Daikin 500 Gas Heater

A flame delay is one of the most frustrating problems a homeowner can face with a gas heater. When the unit fails to ignite or lags behind its normal startup sequence, it can feel like the heater has decided to take a coffee break. This is not only inconvenient, it can also signal a deeper safety issue. If you own a Daikin 500 gas heater and are dealing with a flame delay, you are not alone. This guide will walk you through the common causes, diagnostic steps, and practical solutions to get your heater running reliably again.


The Basics of Flame Initiation

The Daikin 500 uses a combination of sensors and safety interlocks to start safely and efficiently. The sequence is:

  1. Power Check – The unit verifies that it has a proper electrical supply.
  2. Gas Supply – The gas valve opens only when the control board receives a valid signal.
  3. Ignition – A spark or hot surface igniter lights the gas.
  4. Flame Sensor Confirmation – A flame sensor confirms that the flame is stable.
  5. Thermostat Activation – The heater then turns on the blower to warm the room.

A delay usually occurs between steps 2 and 4. The gas may open, but the igniter fails to spark, or the flame sensor does not confirm combustion. Both scenarios will trigger the heater’s safety shutdown and generate a flame‑delay alarm on the display.


Common Culprits of Flame Delay

Cause Why It Happens Typical Symptoms
Dirty or Faulty Igniter Heat‑tolerant surfaces can accumulate residue from low‑grade gas or from a long period of inactivity. The heater clicks but never lights; repeated attempts cause the unit to cycle off.
Worn Flame Sensor The sensor’s metal element oxidizes over time or becomes coated with carbon. The heater lights but then shuts down after a few seconds.
Low Gas Pressure The main gas line or the regulator may be partially closed or damaged. The heater starts but the flame is weak or flickers.
Blocked Air Intake Dust, debris, or an obstructed filter reduces airflow to the combustion chamber. The heater warms up slowly, and the flame appears weak.
Electrical Issues Loose wiring, a failing control board, or voltage irregularities. Random power failures or error codes on the display.
Faulty Gas Valve The valve may fail to open fully or open too slowly. The heater takes unusually long to ignite, or the flame never appears.

These are the most common scenarios that cause a flame delay. The next sections will guide you through diagnosing each one and applying the appropriate fix.


Preparing for Troubleshooting

Safety First – Gas appliances carry inherent risks. Follow these steps before starting:

  1. Turn Off the Power – Switch off the breaker that supplies the heater.
  2. Shut Off the Gas – Locate the main gas valve and close it.
  3. Ventilate the Area – Open windows or use a fan to disperse any residual gas.
  4. Read the Manual – Each Daikin 500 model may have specific steps for maintenance.

Once you’ve completed these safety steps, you can begin inspecting the unit. Remember to keep the area clean and free of clutter while working.


Step‑by‑Step Troubleshooting Guide

1. Verify Power Supply

  • Check the Circuit Breaker – Ensure the breaker is in the “ON” position and not tripped.
  • Test the Outlet – Use a multimeter or a known good appliance to confirm voltage.

If there’s a power issue, resolve it before moving to the gas side. Power problems can masquerade as flame delays because the heater cannot signal the gas valve to open.

2. Inspect the Gas Supply

  • Locate the Main Valve – It’s usually near the furnace or at the main gas line.
  • Open the Valve – Slowly turn the valve fully open.
  • Check for Leaks – Use a soapy water solution on all connections; bubbles indicate a leak.

If the valve is partially closed or leaking, replace the valve or tighten the connections. A low pressure reading may require a professional to check the regulator.

3. Examine the Igniter

  • Access the Igniter – Open the service panel on the front of the heater.
  • Visual Inspection – Look for discoloration, soot, or buildup on the igniter surface.
  • Functional Test – Some units have a “spark test” button; if your model does, press it and listen for a click.

If the igniter is dirty, clean it gently with a soft brush. If it’s not sparking, consider replacing the igniter according to the manufacturer’s instructions.

4. Check the Flame Sensor

  • Locate the Sensor – It sits adjacent to the burner and is usually a small metal probe.
  • Clean the Sensor – Use a fine grit sandpaper or a brass brush to remove oxidation.
  • Re‑install – Ensure the sensor is seated firmly; a loose sensor can misread flame presence.

After cleaning, attempt to start the unit. A properly functioning sensor will confirm the flame, allowing the heater to continue to cycle on.

5. Evaluate Air Intake and Filter

  • Inspect the Filter – If your model has a filter, check if it’s clogged.
  • Clear the Intake – Remove any visible debris from the intake vent.
  • Confirm Proper Airflow – Feel the air entering the unit; it should be steady.

A blocked air path can cause the flame to be weak or unstable, prompting a flame‑delay error. Replace or clean the filter as needed.

6. Assess the Control Board

  • Look for Damage – Burn marks, cracked components, or loose wires may indicate a fault.
  • Test with a Multimeter – Verify continuity on critical pins, especially those controlling the gas valve.
  • Replace if Necessary – If the board shows signs of failure, contact a Daikin‑certified technician for replacement.

Control board issues are less common but can be the root of intermittent flame delays.

7. Examine the Gas Valve

  • Manual Test – Listen for a faint click when the heater attempts to start.
  • Measure Voltage – Use a multimeter to confirm the control board is sending a signal.
  • Physical Inspection – Check for signs of wear or corrosion.

If the valve is not opening fully, it may need to be replaced. Never attempt to repair a gas valve yourself unless you are qualified.


When to Call a Professional

  • Persistent Flame Delays – If you’ve tried all the steps above and the problem persists.
  • Gas Leaks – Any sign of gas leakage requires immediate professional attention.
  • Electrical Faults – Complex control board issues or major wiring problems.
  • Regulatory Compliance – In many regions, gas heater repairs must be performed by licensed technicians.

A certified technician can run more sophisticated diagnostics, such as pressure tests or high‑resolution sensor checks, ensuring your heater operates safely.


Preventive Maintenance Tips

Regular upkeep can reduce the likelihood of flame delays:

  • Annual Service – Schedule a yearly check with a qualified technician.
  • Filter Replacement – Change or clean the filter every 3‑6 months.
  • Igniter & Sensor Cleaning – Clean these components at least once a year.
  • Gas Line Inspection – Have your gas lines inspected every 2‑3 years.
  • Keep the Unit Clean – Dust and debris can accumulate and impede airflow.

Implementing a maintenance routine is a proactive way to avoid the frustration of a flame delay.


Common Questions (FAQ)

Q: My Daikin 500 starts but shuts down after a few seconds. What is wrong?
A: This often points to a faulty flame sensor. Clean or replace the sensor.

Q: The heater clicks but never lights.
A: The igniter may be dirty or defective. Inspect and clean or replace the igniter.

Q: I heard a gas smell when the heater was running. Should I be worried?
A: Absolutely. Gas odors indicate a leak or improper venting. Turn off the gas, ventilate the area, and call a professional immediately.

Q: Can I ignore a flame‑delay warning if the heater seems fine otherwise?
A: No. A flame‑delay warning means the unit detected a safety condition. Ignoring it could lead to hazardous situations.


Conclusion

A flame delay on a Daikin 500 gas heater is not just an annoyance; it is a safety concern that must be addressed promptly. By following the systematic troubleshooting steps above, you can often identify and correct the issue on your own. When in doubt, or if the problem persists, reach out to a certified professional to ensure your home remains warm and safe. Regular maintenance, vigilant inspection, and timely repairs are the keys to reliable heating performance and peace of mind.

Discussion (9)

SV
Svetlana 3 months ago
yo daikin is mad sus if it doth delay. i gots a heater that just whine and ain't flame up. i fix it by just hit the reset button. but that’s all i get
DA
Darya 3 months ago
Svet, resetting is not a fix. It might help with a temporary glitch but the underlying issue is still there. Clean the sensor or check the gas valve.
AU
Aurelius 3 months ago
The flame delay can be a pain, but checking the gas valve and the flame sensor often solves it. I replaced the sensor on my Daikin 500 last week and it worked like a charm.
QU
Quillan 3 months ago
Sounds good. I just swapped the spark module on mine, and the delay vanished. Did you check the pressure regulator too?
IL
Ilya 3 months ago
Does anyone know if the Daikin 500 will do a hard reset with the remote? I’ve tried pressing the green button but nothing changes.
CI
Ciro 3 months ago
I think the flame delay is just a software bug. Just reboot the unit like a router. I did that and it worked.
MA
Marcellus 3 months ago
Rebooting the unit won't fix a flame delay. The issue is hardware – either the flame sensor or the gas valve. Software updates are for the firmware, not the flame.
TE
Teodora 3 months ago
I had a similar issue last month. My unit would start but the flame would not ignite until after 30 seconds. I did the following: checked the gas line pressure – it was fine; tested the flame sensor – it was dirty; cleaned it; checked the spark module – replaced it; also verified that the pressure regulator was set to 6 psi. After those steps the delay disappeared. If your heater is older, consider a quick check of the thermocouple too. It can be a cheap fix.
NI
Niko 2 months ago
Nice rundown. I think the key is also to make sure the airflow is adequate. The vents were partially blocked in my house, so when I opened them the delay went away.
ZO
Zofia 2 months ago
Are you sure the sensor is the issue? I read that the issue might be with the thermostat wiring. That post about Daikin 500 was too generic.
DA
Darya 2 months ago
I got it from the service manual, the sensor is a common culprit. But you might also want to verify the voltage at the flame control board. I found a 24V drop that caused a delay.
DA
Darya 2 months ago
If you’re still stuck, give the technician a call. I got one last week and he fixed it in 30 minutes. Thanks to all of you for the tips.
TE
Teodora 2 months ago
I didn’t use the remote either. The manual says hold the power button for 5 seconds on the unit itself. That worked for me. Remote won’t help.
VE
Vesper 2 months ago
If you’re dealing with a flame delay on a Daikin 500, you’re basically looking at two failure modes: either the low‑pressure switch is stuck or the igniter is weak. The low‑pressure switch should be tested with a multimeter for continuity. If it’s open, replace it. For the igniter, measure the current draw – it should be around 5 amperes. If it’s below 3, it’s time for a new one. Also, never forget that the safety interlock on the gas valve can trip if the flame fails to start within 15 seconds.
IL
Ilya 2 months ago
Wait, the igniter draws 5 amps? I thought it was like 2 amps. Are you sure?

Join the Discussion

Contents

Vesper If you’re dealing with a flame delay on a Daikin 500, you’re basically looking at two failure modes: either the low‑pres... on Resolving a Flame Delay on the Daikin 50... Aug 06, 2025 |
Teodora I didn’t use the remote either. The manual says hold the power button for 5 seconds on the unit itself. That worked for... on Resolving a Flame Delay on the Daikin 50... Aug 05, 2025 |
Darya If you’re still stuck, give the technician a call. I got one last week and he fixed it in 30 minutes. Thanks to all of y... on Resolving a Flame Delay on the Daikin 50... Aug 04, 2025 |
Zofia Are you sure the sensor is the issue? I read that the issue might be with the thermostat wiring. That post about Daikin... on Resolving a Flame Delay on the Daikin 50... Jul 26, 2025 |
Teodora I had a similar issue last month. My unit would start but the flame would not ignite until after 30 seconds. I did the f... on Resolving a Flame Delay on the Daikin 50... Jul 24, 2025 |
Ciro I think the flame delay is just a software bug. Just reboot the unit like a router. I did that and it worked. on Resolving a Flame Delay on the Daikin 50... Jul 19, 2025 |
Ilya Does anyone know if the Daikin 500 will do a hard reset with the remote? I’ve tried pressing the green button but nothin... on Resolving a Flame Delay on the Daikin 50... Jul 18, 2025 |
Aurelius The flame delay can be a pain, but checking the gas valve and the flame sensor often solves it. I replaced the sensor on... on Resolving a Flame Delay on the Daikin 50... Jul 16, 2025 |
Svetlana yo daikin is mad sus if it doth delay. i gots a heater that just whine and ain't flame up. i fix it by just hit the rese... on Resolving a Flame Delay on the Daikin 50... Jul 16, 2025 |
Vesper If you’re dealing with a flame delay on a Daikin 500, you’re basically looking at two failure modes: either the low‑pres... on Resolving a Flame Delay on the Daikin 50... Aug 06, 2025 |
Teodora I didn’t use the remote either. The manual says hold the power button for 5 seconds on the unit itself. That worked for... on Resolving a Flame Delay on the Daikin 50... Aug 05, 2025 |
Darya If you’re still stuck, give the technician a call. I got one last week and he fixed it in 30 minutes. Thanks to all of y... on Resolving a Flame Delay on the Daikin 50... Aug 04, 2025 |
Zofia Are you sure the sensor is the issue? I read that the issue might be with the thermostat wiring. That post about Daikin... on Resolving a Flame Delay on the Daikin 50... Jul 26, 2025 |
Teodora I had a similar issue last month. My unit would start but the flame would not ignite until after 30 seconds. I did the f... on Resolving a Flame Delay on the Daikin 50... Jul 24, 2025 |
Ciro I think the flame delay is just a software bug. Just reboot the unit like a router. I did that and it worked. on Resolving a Flame Delay on the Daikin 50... Jul 19, 2025 |
Ilya Does anyone know if the Daikin 500 will do a hard reset with the remote? I’ve tried pressing the green button but nothin... on Resolving a Flame Delay on the Daikin 50... Jul 18, 2025 |
Aurelius The flame delay can be a pain, but checking the gas valve and the flame sensor often solves it. I replaced the sensor on... on Resolving a Flame Delay on the Daikin 50... Jul 16, 2025 |
Svetlana yo daikin is mad sus if it doth delay. i gots a heater that just whine and ain't flame up. i fix it by just hit the rese... on Resolving a Flame Delay on the Daikin 50... Jul 16, 2025 |