HOME APPLIANCES

Honeywell AH25 Fix for Recurring Power Surges

8 min read
#HVAC Maintenance #Power Surge #Smart Home #Electrical troubleshooting #Honeywell AH25
Honeywell AH25 Fix for Recurring Power Surges

Introduction

Power surges are a common annoyance for many homeowners, but when they occur repeatedly on a Honeywell AH25 air‑conditioning unit, they can hint at deeper electrical or mechanical issues. Unlike occasional spikes caused by grid fluctuations, recurring surges often arise from internal faults such as a faulty capacitor, a deteriorated capacitor, or a problematic compressor relay. This guide provides a thorough, step‑by‑step method for diagnosing, fixing, and preventing persistent power surges on the Honeywell AH25. It assumes that the reader has a basic understanding of home electrical systems and is comfortable following safety precautions.

Understanding the Problem

Power surges manifest as sudden spikes in voltage that can be felt as a “jolt” in the AC unit’s operation, cause the compressor to cycle on and off erratically, or trigger the safety cutoff in the thermostat. On the Honeywell AH25, the surge is most often linked to the start‑up current of the compressor or to the capacitors that feed that current. A surge can damage electronic components, reduce compressor life, and reduce overall efficiency.

Before you start working on the unit, it is essential to understand the key parts involved:

  • Compressor – The heart of the AC that requires a high inrush current during start‑up.
  • Start Capacitor – Provides the initial torque to the compressor motor.
  • Run Capacitor – Keeps the compressor running efficiently once started.
  • Compressor Relay – Controls the power flow to the compressor.
  • Control Board – Houses the electronic logic that manages temperature and timing.

When one of these components fails or degrades, the unit may draw more current than normal, leading to a surge that trips breakers or alarms.

Common Causes of Recurring Surges

Component Typical Issue How It Manifests
Start Capacitor Dry or cracked case, internal leakage Sudden surge on start, compressor fails to spin
Run Capacitor Reduced capacitance, moisture intrusion Continuous high current draw, poor cooling
Compressor Relay Faulty contacts, stuck relay Repeated surges each time the compressor tries to start
Power Supply Overloaded circuit, poor grounding Frequent breaker trips, voltage drops
Control Board Bad ICs, burnt traces Unpredictable behavior, surges detected by diagnostic mode

While each of these issues can produce a surge, the most common culprit on an AH25 is a failing start capacitor or a misbehaving compressor relay. The following sections walk through how to identify, replace, and test these parts.

Safety Precautions

Safety should be your first priority. Follow these steps before you touch the unit:

  • Turn off the main circuit breaker that supplies power to the AH25. Use a voltage tester to confirm the unit is de‑energized.
  • Wear insulated gloves and safety glasses. Even when the unit is off, capacitors can hold charge.
  • Disconnect the thermostat or any remote control that might send signals to the compressor.
  • Keep a fire extinguisher nearby in case of sparks or overheating.
  • Avoid working in damp or humid environments that could cause static discharge or interfere with components.

If you are not comfortable with electrical work, consider hiring a licensed HVAC technician.

Step‑by‑Step Troubleshooting

  1. Visual Inspection
    Open the AH25 front panel using a Phillips head screwdriver. Look for signs of damage: swollen capacitors, burn marks, or discolored wires. A swollen capacitor will appear larger than normal and may have a bulging metal case.

  2. Measure Capacitor Capacity
    Use a multimeter set to the capacitance range. Disconnect the capacitor from the circuit, ensuring the unit is still de‑energized. Place the meter leads on the capacitor terminals and read the value. Compare it to the rating printed on the capacitor label.

    • Start Capacitor should be within 80–120 % of its rated value.
    • Run Capacitor should be within 70–110 % of its rated value.

    If either reading falls outside the acceptable range, replace the capacitor.

  3. Check the Compressor Relay
    The relay is usually a small rectangular board with multiple pins. Look for signs of corrosion or burnt components. Test the relay by:

    • Removing it from the circuit.
    • Applying a 24‑V DC supply across the coil pins.
    • Measuring the resistance between the normally open and normally closed contacts.
    • If the resistance readings are abnormal (very high or low), replace the relay.
  4. Inspect the Control Board
    Examine the PCB for burnt resistors, blown capacitors, or cracked solder joints. Use a magnifying glass if necessary. If you find damaged components, you may need to replace the board entirely.

  5. Verify Wiring and Connections
    Tighten any loose screws and ensure all wire connections are secure. Look for frayed or damaged insulation that could cause a short circuit.

  6. Grounding Check
    Confirm that the unit’s grounding strap is connected to a solid grounding rod or the building’s grounding system. A poor ground can increase the likelihood of surges.

  7. Re‑assemble and Test
    After replacing any faulty parts, carefully re‑assemble the unit. Re‑apply the thermostat and turn the main breaker back on. Observe the unit’s operation. If the power surge stops, you have successfully resolved the issue.

Replacing Faulty Components

Replacing a Start Capacitor

  1. Locate the start capacitor on the compressor assembly.
  2. Note the polarity: one terminal is usually marked “+”.
  3. Disconnect the leads from the capacitor.
  4. Remove the old capacitor with a pair of pliers.
  5. Insert the new capacitor, ensuring correct polarity.
  6. Tighten the terminals securely.

Replacing a Run Capacitor

The run capacitor is often located on the control board or near the compressor. Follow the same procedure as for the start capacitor, but ensure you use the correct voltage rating, typically 50 V or 60 V, depending on your model.

Replacing a Compressor Relay

  1. Unplug the AH25 from the power source.
  2. Remove the relay by loosening the mounting screws.
  3. Replace it with an identical relay (match the coil voltage and contact rating).
  4. Re‑install the relay and secure it with screws.

Replacing the Control Board

If the control board shows damage, buy a replacement from Honeywell’s official parts distributor. Follow the manufacturer’s instructions for removal and installation. Do not attempt to repair individual components on the board unless you have proper soldering skills and equipment.

Testing and Verification

After all replacements are complete, conduct the following tests to confirm the fix:

  • Voltage Drop Test
    With a multimeter, measure the line voltage at the unit’s power inlet. It should read between 115 V and 120 V. A significant drop indicates a larger issue.

  • Start‑Up Current Measurement
    Use an ammeter in series with the compressor. On start‑up, the current should spike briefly but not exceed the compressor’s rated inrush current (typically 10–15 A). Excessive inrush suggests a relay or capacitor problem still exists.

  • Operational Test
    Run the AC for at least 30 minutes. Ensure the compressor cycles normally and that the thermostat registers the correct temperature. Listen for any unusual noises or vibrations.

  • Surge Monitoring
    Attach a surge protector or a simple voltage logger to the unit’s power line for a few hours. Confirm that no spikes above 150 V are recorded.

If all tests are satisfactory, the unit should operate without further power surges.

Preventive Measures

Even after fixing the current issue, it is wise to implement preventive steps to avoid future surges:

  • Install a Whole‑House Surge Protector
    A high‑quality surge protector at the main breaker can absorb unexpected spikes before they reach the HVAC system.

  • Regular Maintenance Checks
    Schedule a yearly inspection by a qualified HVAC technician. They can clean coils, lubricate motors, and check for early signs of capacitor degradation.

  • Upgrade the Capacitors
    If your AH25 is more than ten years old, consider replacing both capacitors with modern, low‑ESR (Equivalent Series Resistance) models. These are more resistant to heat and moisture.

  • Grounding System Inspection
    Verify that the building’s grounding system remains intact. Replace corroded grounding rods or conductors as needed.

  • Use Quality Replacements
    When ordering spare parts, always choose OEM or OEM‑approved components. Cheap knock‑offs can fail prematurely and cause surges.

Conclusion

Recurring power surges on a Honeywell AH25 are usually a symptom of a failing start or run capacitor, a defective compressor relay, or a damaged control board. By carefully inspecting each component, measuring capacitance, testing relays, and replacing faulty parts, you can restore the unit’s stability and extend its lifespan. Always follow safety precautions, use the correct replacement parts, and perform thorough testing after repairs. For ongoing reliability, invest in a surge protector and schedule regular maintenance. With these measures in place, your AH25 will run smoothly, keeping your home comfortable and your electrical system protected.

Discussion (10)

VI
Viktor 11 months ago
I’m not convinced you should be fiddling with the compressor relay yourself. Those parts are pricey and the unit is sealed. In my house, a recurring surge was actually a loose neutral in the panel. After the electrician tightened it, everything behaved.
CA
Cassio 11 months ago
Look, if you’re comfortable with a multimeter, you can check the relay resistance. It’s not rocket science. Just make sure you discharge the caps first.
DA
Daphne 11 months ago
Honestly, unless you’re certified, call an HVAC tech. A mistake can fry the whole system and your warranty.
MI
Miriam 11 months ago
Yo, that guide be straight fire. If ur unit keep trippin, just swap that cap like a boss, no need to call the geek squad.
XA
Xav 11 months ago
I read the post and thought, why not just stick a toaster in the unit to test the surge? lol what could go wrong.
LU
Lucrezia 11 months ago
Do NOT do that. A toaster will just draw more current and likely damage the unit or start a fire. Use a proper surge tester or multimeter.
YA
Yara 11 months ago
I’ve been through three AH25s in the last five years. The first two died after a few months of recurring surges, which we traced back to a failing start capacitor. On the third unit we finally followed the step‑by‑step from this article: turned off power, discharged the caps, measured both the start and run caps, replaced the start cap with a genuine 30 µF 450 V part, and tightened the relay connections. After that, the unit has been solid for over a year. A couple of takeaways – always double‑check the voltage rating, never skip the discharge step (it can give you a nasty shock), and if the breaker still trips after the cap swap, suspect a loose neutral or a faulty relay. Also, keep all photos of the old parts; some HVAC techs will give you a discount if you show them what failed. Good luck to anyone still battling this beast.
EL
Eloise 11 months ago
so the article says replace the cap, but i think it's just the power company messing with us.
LA
Lazzaro 11 months ago
I followed the capacitor test walk‑through from the guide and actually caught a bulged one. Swapped it out with a new 35 µF and the surges stopped. Had to turn off the breaker for a good 5 minutes before pulling the old part, otherwise the unit kept kicking back.
MA
Marek 11 months ago
Nice work, Lazzaro! Did you also check the relay coil resistance? I had a unit that kept tripping the breaker even after the cap was fine.
SO
Sophronia 11 months ago
The relay is indeed a common culprit. Measure it at about 70 Ω when cold; anything higher means it's about to fail.
OL
Olivier 11 months ago
My unit is still under the one‑year warranty. If I replace the capacitor myself, does that void it? The guide suggests DIY, but I'm wary of breaking the terms.
ST
Stella 11 months ago
Warranty usually stays intact as long as you use OEM parts and don’t cause collateral damage. Keep the receipt and maybe notify the dealer.
RO
Rostislav 11 months ago
i doubt any of this works. the AH25 is a junk unit, just replace it.
PA
Pax 10 months ago
i had the same ah25 buzzing every summer. turned off the main, pulled the front panel, found the old cap leaking. swapped it, now it runs quiet. cheap fix, dont overthink it.
BR
Brontë 10 months ago
According to the Honeycomb service manual (section 4.2), the AH25 uses a dual‑run capacitor rated 5 µF‑30 µF 450 V. Using a single‑run part will cause the compressor to overheat and trigger the surge protector. The article omits this critical spec.
GI
Giosue 10 months ago
Actually, the manual lists the cap as 5 µF for the fan and 30 µF for the compressor, not a dual‑run. The guide was correct on using a single‑run 30 µF for the compressor side.

Join the Discussion

Contents

Brontë According to the Honeycomb service manual (section 4.2), the AH25 uses a dual‑run capacitor rated 5 µF‑30 µF 450 V. Usin... on Honeywell AH25 Fix for Recurring Power S... Nov 26, 2024 |
Pax i had the same ah25 buzzing every summer. turned off the main, pulled the front panel, found the old cap leaking. swappe... on Honeywell AH25 Fix for Recurring Power S... Nov 26, 2024 |
Rostislav i doubt any of this works. the AH25 is a junk unit, just replace it. on Honeywell AH25 Fix for Recurring Power S... Nov 22, 2024 |
Olivier My unit is still under the one‑year warranty. If I replace the capacitor myself, does that void it? The guide suggests D... on Honeywell AH25 Fix for Recurring Power S... Nov 20, 2024 |
Lazzaro I followed the capacitor test walk‑through from the guide and actually caught a bulged one. Swapped it out with a new 35... on Honeywell AH25 Fix for Recurring Power S... Nov 19, 2024 |
Eloise so the article says replace the cap, but i think it's just the power company messing with us. on Honeywell AH25 Fix for Recurring Power S... Nov 17, 2024 |
Yara I’ve been through three AH25s in the last five years. The first two died after a few months of recurring surges, which w... on Honeywell AH25 Fix for Recurring Power S... Nov 16, 2024 |
Xav I read the post and thought, why not just stick a toaster in the unit to test the surge? lol what could go wrong. on Honeywell AH25 Fix for Recurring Power S... Nov 15, 2024 |
Miriam Yo, that guide be straight fire. If ur unit keep trippin, just swap that cap like a boss, no need to call the geek squad... on Honeywell AH25 Fix for Recurring Power S... Nov 06, 2024 |
Viktor I’m not convinced you should be fiddling with the compressor relay yourself. Those parts are pricey and the unit is seal... on Honeywell AH25 Fix for Recurring Power S... Nov 04, 2024 |
Brontë According to the Honeycomb service manual (section 4.2), the AH25 uses a dual‑run capacitor rated 5 µF‑30 µF 450 V. Usin... on Honeywell AH25 Fix for Recurring Power S... Nov 26, 2024 |
Pax i had the same ah25 buzzing every summer. turned off the main, pulled the front panel, found the old cap leaking. swappe... on Honeywell AH25 Fix for Recurring Power S... Nov 26, 2024 |
Rostislav i doubt any of this works. the AH25 is a junk unit, just replace it. on Honeywell AH25 Fix for Recurring Power S... Nov 22, 2024 |
Olivier My unit is still under the one‑year warranty. If I replace the capacitor myself, does that void it? The guide suggests D... on Honeywell AH25 Fix for Recurring Power S... Nov 20, 2024 |
Lazzaro I followed the capacitor test walk‑through from the guide and actually caught a bulged one. Swapped it out with a new 35... on Honeywell AH25 Fix for Recurring Power S... Nov 19, 2024 |
Eloise so the article says replace the cap, but i think it's just the power company messing with us. on Honeywell AH25 Fix for Recurring Power S... Nov 17, 2024 |
Yara I’ve been through three AH25s in the last five years. The first two died after a few months of recurring surges, which w... on Honeywell AH25 Fix for Recurring Power S... Nov 16, 2024 |
Xav I read the post and thought, why not just stick a toaster in the unit to test the surge? lol what could go wrong. on Honeywell AH25 Fix for Recurring Power S... Nov 15, 2024 |
Miriam Yo, that guide be straight fire. If ur unit keep trippin, just swap that cap like a boss, no need to call the geek squad... on Honeywell AH25 Fix for Recurring Power S... Nov 06, 2024 |
Viktor I’m not convinced you should be fiddling with the compressor relay yourself. Those parts are pricey and the unit is seal... on Honeywell AH25 Fix for Recurring Power S... Nov 04, 2024 |