HOME APPLIANCES

Troubleshooting the Honeywell T5 Heater Overheating Issue

8 min read
#troubleshooting #Honeywell T5 #Heater Overheating #HVAC #Thermostat

Introduction

The Honeywell T5 heater is a popular choice for homeowners who need quick, reliable heat in a compact unit. Like any heating appliance, it can sometimes develop a problem where the unit becomes excessively hot or triggers a safety shutdown. Understanding the root causes and following a systematic troubleshooting approach can save time, money, and potential safety risks.

This guide walks you through common overheating scenarios, explains the underlying mechanisms, and provides step‑by‑step solutions. It is written in plain English and uses a clear, organized structure so you can find the information you need quickly.


What Does “Overheating” Mean for the T5?

When a T5 heater is said to be overheating, it generally falls into one of these three categories:

  1. Thermostat‑Triggered Safety Shut‑Off – The heater’s internal temperature sensor signals that it is too hot, so the unit powers down automatically, a scenario similar to the bypassing auto shutoff on the Carrier CHT-3500 Gas Heater issue.
  2. Visible Excess Heat – The heater’s surface or the surrounding air feels unusually hot to the touch, even if it has not shut down.
  3. Unexplained Power Draw – The heater consumes more electrical current than normal, causing the circuit breaker to trip or a surge protector to warn of high load.

Knowing which of these applies will help you pinpoint the right fix.


Safety First

Before you open the unit or manipulate its wiring, follow these safety steps:

  • Turn off the power at the breaker or unplug the heater from the outlet.
  • Let the heater cool completely; it can stay hot for up to 30 minutes after operation.
  • Use insulated gloves when touching internal components.
  • Never attempt a repair if you are not comfortable with electrical work; call a licensed electrician instead.

Step 1: Inspect the External Condition

  1. Check for Blockages
    The T5 heater has a filter grille at the front. If dust, pet hair, or debris block airflow, the unit may overheat.

    • Remove the grille by unscrewing the two corner screws.
    • Clean with a vacuum or a soft brush.
    • Reinstall the grille and test.
  2. Look for Physical Damage

    • Inspect the heating element for burn marks, melted plastic, or discolored areas.
    • Any visible damage indicates that the element may have failed and should be replaced.
  3. Confirm Proper Placement

    • The heater should be placed on a hard, stable surface.
    • It must not be positioned too close to walls, ceilings, or any flammable material.
    • Ensure there is at least 12 inches of clearance on all sides.

Step 2: Verify the Power Supply

The T5 uses a 120‑V circuit. Overheating can occur if the power supply is inconsistent.

  1. Check the Outlet

    • Use a multimeter set to 120 V AC.
    • Verify that the outlet supplies steady voltage.
    • A fluctuating voltage can stress the heater’s components.
  2. Confirm the Circuit

  3. Examine the Wiring

    • If you are comfortable, open the back cover to inspect the wiring harness.
    • Look for loose connections or frayed insulation.
    • Tighten any loose terminals with a Phillips screwdriver.

Step 3: Test the Temperature Sensor (Thermostat)

The T5’s safety shut‑off relies on a temperature sensor that triggers a cut‑off at 155 °F (68 °C). A faulty sensor can falsely signal overheating.

  1. Locate the Sensor

    • Inside the heater’s case, near the heating element, there is a small metal probe.
  2. Measure the Resistance

    • Disconnect the sensor wire from the harness.
    • Use a multimeter in the ohm range.
    • At room temperature ( 70 °F), the resistance should read between 5 kΩ and 10 kΩ (exact spec may vary; refer to the service manual).
  3. Interpret the Reading

    • Below 5 kΩ: The sensor is likely shorted and should be replaced.
    • Above 10 kΩ: The sensor may be open or damaged.
    • Within spec: The sensor is likely fine, but proceed to the next step for confirmation.
  4. Replace If Needed


Step 4: Examine the Heating Element

If the element is burning hotter than it should, it can cause the sensor to trip.

  1. Visual Inspection

    • The element is a coiled metal wire that looks like a small furnace.
    • Burned ends or discoloration indicate failure.
  2. Temperature Test

    • Reconnect the heater and power it on in a safe location.
    • Use a digital thermometer to measure the element’s surface temperature after a few minutes of operation.
    • It should not exceed 350 °F (177 °C). Anything higher is a sign of malfunction.
  3. Replacement Procedure

    • Unplug the heater and wait for the element to cool.
    • Locate the element’s mounting screws.
    • Unscrew and remove the old element.
    • Insert the new element, tighten the screws evenly, and reconnect any wire terminals.

Step 5: Evaluate Airflow and Ventilation

Heat can build up if there is insufficient airflow. The T5’s fan and vent design rely on a steady airflow path.

  1. Check the Fan

  2. Test the Vent Path

    • Stand in front of the heater and feel for cool air coming out of the vent.
    • If the vent feels very hot or has little airflow, there may be a blockage in the ducting.
    • Inspect the vent pipe for obstructions or kinks.
  3. Adjust the Height

    • The T5 should be installed with its bottom about 18 inches above the floor.
    • If it is too low, hot air may accumulate near the floor and not circulate properly.

Step 6: Reset and Observe

After performing the above checks and fixes:

  1. Reset the Heater

    • Locate the reset button on the control panel.
    • Press and hold for 5 seconds until the indicator lights stabilize.
  2. Monitor the Heater

    • Let it run for 30 minutes.
    • Observe whether the indicator light remains on or if it turns off prematurely.
    • Note any changes in temperature readings or airflow.
  3. Record Observations

    • Document the time it takes to reach the set temperature.
    • Log the heater’s operating temperature at regular intervals.
    • If the heater still behaves erratically, return to earlier steps for further investigation.

Common Root Causes Summarized

Issue Likely Cause Quick Fix
Thermostat trips too soon Faulty temperature sensor Replace sensor
Surface feels excessively hot Dirty or damaged filter grille Clean grille
Heater fails to heat at all Burned heating element Replace element
Power draw too high Circuit overloaded Move to dedicated circuit
Airflow obstructed Fan debris or vent blockage Clean fan, clear vent

When to Call a Professional

If after following all steps the heater continues to overheat or exhibit safety shutdowns, it may indicate a deeper electrical or mechanical failure. In that case:

  • Call a licensed electrician for wiring or circuit issues.
  • Contact Honeywell support for parts replacement or warranty service if the unit is still under warranty.
  • Consider replacing the unit if repair costs exceed the value of the heater.

Maintenance Checklist for Longevity

Frequency Action
Every 3 months Clean filter grille
Every 6 months Inspect and clean fan blades
Annually Check temperature sensor and heating element
As needed Verify proper ventilation and clearance

Keeping these tasks on schedule helps prevent overheating and extends the life of your Honeywell T5 heater.


FAQ

Q: Does the heater use a thermostat setting?
A: The T5 has a fixed heat output and does not allow temperature adjustment via a built‑in thermostat. The user controls the heat by turning the unit on or off.

Q: Can I use the heater in a small room with no ventilation?
A: The heater should always have a minimum of 12 inches clearance and adequate airflow. Operating it in a tightly sealed space can cause heat buildup.

Q: What if the heater smells burnt?
A: A burnt smell usually means the element has failed. Replace it immediately and reset the heater.


Conclusion

Troubleshooting the Honeywell T5 heater overheating issue involves a systematic approach: check external conditions, verify the power supply, test the temperature sensor, inspect the heating element, and evaluate airflow. By following the step‑by‑step guide above, you can identify and correct common problems, ensuring safe and efficient operation. Regular maintenance and awareness of the heater’s specifications will help you avoid future overheating incidents and keep your home warm and comfortable.

Discussion (7)

IV
Ivan 1 year ago
I had a weird issue: the unit would hit 120°F then shut down. I followed the article, unplugged for 30 mins, and it came back fine. Looks like a thermal fuse issue, but the guide made it easy.
MA
Marco 1 year ago
I ran into that same overheating on my T5 last night. The article was spot on with the vent blockage. Just had to clean the intake, and it was good as new.
LU
Lucia 1 year ago
Just read the post and realized that my T5's temperature sensor had a loose wire. I didn't think that could cause overheating, but now I see how. Thanks for pointing that out.
AN
Anna 1 year ago
Not convinced the vent blockage is the only cause. I've seen units overheat with no obvious blockage. Maybe the thermostat sensor is failing? The article doesn't cover that.
MA
Marco 1 year ago
Anna, I also checked my vent – it was clogged with dust. Once I cleaned it, the temperature dropped. The thermostat was fine.
SE
Sebastian 1 year ago
Anna, I agree. Vents can be a problem, but I've seen overheating with vents clear. Voltage and wiring are key factors.
SE
Sebastian 1 year ago
As a HVAC technician, I can say that the article is useful, but it's missing the part about electrical supply voltage variations. A 120V supply at 110% can overheat the unit. Also, you shouldn't ignore the wiring connections. It's not just vents.
IV
Ivan 1 year ago
Seb, thanks. I did check voltage and wiring; they were fine. The thermal fuse seemed to be the culprit after all.
MA
Maya 1 year ago
I think the problem is the thermostat is set to too high, not the heater itself. I've been using 75°F all winter and it still overheat. Maybe I'm wrong.
EL
Elena 1 year ago
Maya, the thermostat is separate from the heater unit. The T5 has an internal temp sensor that can go bad. In my case, I replaced the sensor and fixed the overheating. Setting the thermostat too low won't help.
TO
Tomas 1 year ago
Great article! I just fixed mine by tightening the mounting bracket. The heater was wobbling and that caused heat buildup. Really glad I read it.

Join the Discussion

Contents

Tomas Great article! I just fixed mine by tightening the mounting bracket. The heater was wobbling and that caused heat buildu... on Troubleshooting the Honeywell T5 Heater... Aug 16, 2024 |
Maya I think the problem is the thermostat is set to too high, not the heater itself. I've been using 75°F all winter and it... on Troubleshooting the Honeywell T5 Heater... Aug 14, 2024 |
Sebastian As a HVAC technician, I can say that the article is useful, but it's missing the part about electrical supply voltage va... on Troubleshooting the Honeywell T5 Heater... Aug 09, 2024 |
Anna Not convinced the vent blockage is the only cause. I've seen units overheat with no obvious blockage. Maybe the thermost... on Troubleshooting the Honeywell T5 Heater... Aug 08, 2024 |
Lucia Just read the post and realized that my T5's temperature sensor had a loose wire. I didn't think that could cause overhe... on Troubleshooting the Honeywell T5 Heater... Aug 07, 2024 |
Marco I ran into that same overheating on my T5 last night. The article was spot on with the vent blockage. Just had to clean... on Troubleshooting the Honeywell T5 Heater... Jul 29, 2024 |
Ivan I had a weird issue: the unit would hit 120°F then shut down. I followed the article, unplugged for 30 mins, and it came... on Troubleshooting the Honeywell T5 Heater... Jul 25, 2024 |
Tomas Great article! I just fixed mine by tightening the mounting bracket. The heater was wobbling and that caused heat buildu... on Troubleshooting the Honeywell T5 Heater... Aug 16, 2024 |
Maya I think the problem is the thermostat is set to too high, not the heater itself. I've been using 75°F all winter and it... on Troubleshooting the Honeywell T5 Heater... Aug 14, 2024 |
Sebastian As a HVAC technician, I can say that the article is useful, but it's missing the part about electrical supply voltage va... on Troubleshooting the Honeywell T5 Heater... Aug 09, 2024 |
Anna Not convinced the vent blockage is the only cause. I've seen units overheat with no obvious blockage. Maybe the thermost... on Troubleshooting the Honeywell T5 Heater... Aug 08, 2024 |
Lucia Just read the post and realized that my T5's temperature sensor had a loose wire. I didn't think that could cause overhe... on Troubleshooting the Honeywell T5 Heater... Aug 07, 2024 |
Marco I ran into that same overheating on my T5 last night. The article was spot on with the vent blockage. Just had to clean... on Troubleshooting the Honeywell T5 Heater... Jul 29, 2024 |
Ivan I had a weird issue: the unit would hit 120°F then shut down. I followed the article, unplugged for 30 mins, and it came... on Troubleshooting the Honeywell T5 Heater... Jul 25, 2024 |